Sediment Trap Data Tables
              This collection of sediment trap data was compiled from a combination 
    of published and unpublished sources.  A complete list of published sources is available
	here. 
	Special permission
    was obtained directly from the appropriate researchers to include the unpublished
    data.
  The online database of global sediment trap results, accessed by clicking on the 'Sediment Trap' link at left, 
    represents the most basic calculations and information
    from the sediment trap projects that have collected particle material in
    the deep ocean.  When reported for multiple traps, Duration_d represents the maximum
    duration of deployment (in days) for one of those traps.  Similarly, the "Start Year" 
    indicates the earliest date from that location at which there were multiple trap 
    deployments.  The particle mass flux has been reported to include the >1mm
    size fraction and <1mm size fraction of the particulate material.  The
    elemental analysis is reported on the <1mm size fraction and includes
    organic carbon, inorganic carbon, biogenic silicon, nitrogen and aluminum.
    No dissolved portions of the sample are included, no analysis of the >1mm
    size fraction is reported.  
  The following components are reported in a variety of units and in two separate data sets (annual and time-series): organic carbon, inorganic carbon, biogenic
    silicon, nitrogen and aluminum. 
  The "annual flux data"  contains annual integrated data from each sediment
    trap in mass flux (annual flux in g m-2 yr-1; average annual flux in mg m-2
    d-1) , concentration (%) and mole ratios (C-org/C-inorg, C-org/Si-bio,
    Si-bio/C-inorg, C-org/N and C-org/Al).
  The "time-series flux data", is the original time-series data from each sediment trap
    in mass flux, (mg m-2 d-1) concentration (%), mole ratios (C-org/C-inorg,
    C-org/Si-bio, Si-bio/C-inorg, C-org/N and C-org/Al) and net mass in cup
    (in mg).
  In some cases where published data units had to be converted for inclusion in this dataset, the following calculations were used.
  
  Conversion factors and calculations from references
  C-inorganic flux calculated from CaCO3 flux:
  C-inorg. flux = CaCO3 flux / 8.33
  
  Si-biogenic flux calculated from OPAL flux:
  Si-bio. flux = OPAL (SiO2 with 10% H2O) flux / 2.4
  (Ref. Mortlock and Froelich, 1989)
  Si-bio. flux = OPAL (SiO2) flux / 2.14
  
  C-organic flux calculated from Organic Matter (OM) flux:
  
  C-org. flux = Organic Matter (OM) flux / 1.86
  C-org. flux = Organic Matter (OM) flux / 2.86
  C-org. flux = Organic Matter (OM) flux / 2.5
  
  N-flux calculated from organic carbon flux and C/N mole ratio:
  
  N-flux = C-org. flux / C-org. / N (moles)
  
  Al-total flux calculated from Lithogenic flux:
  Al flux = Lithogenic flux / 12.5
  
  
  Methods
  Preservatives and Poisons used:
  Formaldehyde based (FORM)
  Glutaraldehyde (GLUT)
  Mercuric Chloride based (HgCl2)
  Sodium Azide based (NaN3)
  
  Mass Flux analysis
  Particle samples were removed from the collecting cup and sieved
    through a 1mm sieve. In most cases the <1mm portion was split into several
    working samples. 
  In order to get an accurate weight of the particulate sample, the salt water
    was removed by either centrifugation (CEN) or filtration (FIL).
    The sample was then dried at approximately 60C, desiccated and weighed.  The
    net weight in the cup was then calculated for both >1mm and <1mm size
    fraction. 
  Mass Flux Calculations:
  Mass flux of the >1mm and <1mm size fraction was calculated by dividing
    the net weight in the cup by the trap opening area and the collecting time. The
    following equation was used:
  (mass flux; mg m-2 d-1) = 
   (net wt. in cup; mg) / [(trap opening area; m2)*(cup collecting time; days)]
  Component Mass Flux (C-org., C-inorg., Si-bio., N, and Al) calculations:
  Component mass flux of C-org, C-inorg., Si-bio., N, Al was
    calculated in the <1mm size fraction using the concentration of each component multiplied
    by the <1mm mass flux. 
  (Component mass flux in mg m-2 d-1) = 
  (% component in <1mm/100)* (<1mm mass flux in mg m-2 d-1)
  Component Mole Flux was calculated with the following equations:
  C-org. mole flux in umole m-2 d-1= C-org. mass flux in mg m-2
    d-1 / (12.01 / 1000)
  C-inorg mol flux in umole m-2 d-1 = C-inorg mass flux in mg
    m-2 d-1 / (12.01 / 1000)
  Si-bio. mole flux in umole m-2 d-1 = Si-bio. mass flux in mg
    m-2 d-1 / (28.09 / 1000)
  N mole flux in umole m-2 d-1 = N mass flux in mg m-2 d-1 / (14.01 / 1000)
  Al mole flux in umole m-2 d-1 = Al mass flux in mg m-2 d-1 / (26.98 / 1000)
  Elemental analysis:
  > 1mm size fraction:
  The mass flux and concentration of the >1mm size fraction of the sample
    is reported when available.  No analysis are preformed on the >1mm size
    fraction.
  < 1mm size fraction:
  Elemental analysis is preformed on the <1mm size fraction of the sample.  After
    processing of the <1mm size fraction of the sample, subsamples of the
    dried <1mm size fraction sample were weighed for each analysis. 
	
	
    C-inorganic analysis
	Weight loss analysis (%CaCO3 = %wt. loss after acid treatment): The
    concentration of CaCO3 is calculated by the weight difference between weight
    of the total sample and the weight of the sample after acidification.  The
    weight loss is assumed to be CaCO3 and inorganic carbon is calculated from
    the following equation:  % C-inorganic = %CaCO3/8.33
  Coulometer analysis:  The concentration of inorganic
    Carbon (CO2) is directly quantified by coulometric titration during sample
    acidification.  The
    inorganic carbon (C-inorg.) is calculated as a % of the analyzed sample.
  Gassimetric analysis: The sample is acidified and the evolved CO2
    is manometricly quantified.
  The inorganic carbon (C-inorg.) is calculated as a % of the analyzed sample. 
  Carbon difference ( inorganic C = total C - organic C):  The
    concentration of inorganic carbon quantified by the difference between total
    Carbon and Organic Carbon (acidified sample) as analyzed by a Carbon elemental
    analyzer. 
  Si-biogenic analysis:
  Selective Alkaline dissolution:  The biogenic Si is
    selectively dissolved from the sample by treating the sample with an alkaline
    solution (either
    Na2CO3 or NaOH) with heat for a period of time.  The Si is analyzed by various
    detectors, usually colorimetric spectrophotometer or by ICP-ES.  The concentration
    of Si in the sample is then calculated.
  Total Si and Al analysis.  The sample is totally dissolved by alkaline
    fusion (lithium-meta borate fusion) or by acid digestion (open beaker or
    sealed microwave heating).  The Si and Al in the liquefied sample is analyzed
    by various detectors, (ICP-ES, ICP-MS, AA).  The Si and Al concentration
    are then calculated.  The biogenic Si is calculated by subtracting the lithogenic
    Si fraction from the total Si.  The lithogenic Si fraction of the sample
    is calculated from the product of the Al concentration of the sample and
    the Si/Al crustal ratio (Si/Al =3.4 mass). 
  
  
  
  C-organic analysis  
  Carbon analysis of decalcified sample: A sample is decalcified by
    various acids (HCL, Sulfurous acid, Phosphoric acid) and techniques (direct
    contact, fuming) and is analyzed by a carbon analyzer.  The concentration
    of carbon is reported as % organic carbon of the sample.
  Carbon difference ( organic C = total C - inorganic C):  The concentration
    of organic carbon is quantified by the difference between total carbon content (carbon
    elemental analyzer) and inorganic carbon content (coulometric method) 
  Wet Chemical carbon analysis:  The organic carbon content of the
    sample is extracted by chemical solutions and is determined by a carbon elemental
    analyzer.
  N analysis:
  N in total sample: N was analyzed in the total sample with an elemental
    N analyzer
  N in decalcified sample: N was analyzed in a decalcified sample with
    an elemental N analyzer
  Al analysis:  
  Total Al analysis.  The sample is totally dissolved by alkaline
    fusion (lithium-meta borate fusion) or by acid digestion (open beaker or
    sealed microwave heating).  The Al in the liquefied sample is analyzed by
    various detectors, (ICP-ES, ICP-MS, AA).  The Al concentration as % Al in
    the sample.
  Average daily settling fluxes
  The average daily fluxes were calculated by dividing the sum of the net
    mass in each cup by the trap area multiplied by the collecting time duration 
  
  Average daily settling fluxes = Measured settling fluxes / duration (days)
  Annual settling Fluxes 
  Annual settling fluxes = Measured settling fluxes x 365 / duration (days)