 PI-Note: To convert Beam C (C(1/m)) to Cp the following
                 amount was added to ALL casts:   -0.366

                 In addition the following casts were adjusted:

	97330103        -0.03665
	97330104        -0.04735
	97330302        -0.05805
	97330304        -0.04420
	97330305        -0.04420
	97330401        -0.04420
	97330403        -0.03355
	97330405        -0.03222
	97330406        -0.03177
	97330407        -0.03177
	97330408        -0.03889
	97330409        -0.03177
	97330411        -0.04423
	97330501        -0.01012
	97330502        -0.02027
	97330504        -0.00220
	97330508        -0.00895
	97330509        -0.00748
	97330602        -0.01056
	97330603        -0.00397

 AESOPS Investigators, Please note:
  Begin and end parameters for time, latitude and longitude are
  provided in the core CTD and Bottle data.  Investigators
  submitting data related to CTD/Bottle casts are urged to use
  the single lat/lon entry from the Chief Scientist's event log.

 Parameter   Description                                 Units

event a unique number assigned to each sampling operation consisting of month MM, day DD, hour HH and minute mm sta station number cast CTD rosette cast number date date (YYYYMMDD) decoded as follows YYYY = year, MM = month, DD = day Date converted to GMT time_begin starting time of cast in UTC decimal hours time_end ending time of cast in UTC decimal hours lat_begin starting latitude, negative = south decimal degrees lon_begin starting longitude, negative = west decimal degrees lat_end ending latitude decimal degrees lon_end ending longitude decimal degrees depth depth of sample meters press depth of sample reported as pressure decibars temp temperature, IPTS-68 degrees C cond conductivity CTD milliSiemens/centimeter sal salinity, PSS-78 PSU potemp potental temperature, IPTS-68 degrees C sigma_t sigma t kilograms/meter^3 sigma_0 potental density kilograms/meter^3 beam_cp beam attenuation due to particles 1/meter fluor relative fluorescence, corrected by milligram/meter^3 Seabird software to chlorophyll-a light_bs backscattered light from a Light volts Scattering Sensor nd no/bad data