chl

 PI:             Jan Newton/James Murray
 dataset:        CTD Fluorometric chlorophyll a and total phaeopigment
 project/cruise: EQPAC/TT007
 ship:           Thomas Thompson

 PI note:  Due to chlorophyll degradation by the acetone (reagent grade,
           in cans) the data for the following CTD casts have been deleted
           from the file:  1, 3, 5, 6, 7, 8, 20, 23, 25, 30, 33, 35, 37 and 38.


 Parameter       Description                                     Units 

event event/operation number from event log sta station number from event log cast CTD cast number from event log comment free text data quality notes bot CTD rosette bottle number depth_n nominal sample depth meters fluor_vol_filt volume of sample filtered liters scale sensitivity scale on the fluorometer df door factor; true value of sensitivity scale B undefined Fo original fluorometer reading Fa fluorometer reading after 2 drops 1N HCL chl_a_fluor chlorophyll a; fluorometric method micrograms/liter phaeo total phaeopigment micrograms/liter Fo_to_Fa Fo to Fa ratio. ranges between max. 2.10, all chlorophyll-a no Phaeopigment min. 1.00, no chlorophyll-a all Phaeopigment