# James Murray
# EQPAC TT012
# Comments relating to quality (q_flag)
#
sta	ctd	bot	depth	press	comments
2	1	11	14.9	15	Oxygen draw temperature low; probable pretrip
2	2	12	3.1	3.1	Air vent open
2	2	11	29.1	29.3	Leaking from bottom
2	2	10	99.9	100.5	Air vent open
3	3	11	29.9	30.1	Oxygen draw temperature low; oxygen appears low; possible pretrip or oxygen sample could be switched with #10
3	3	10	100	100.6	Oxygen note says could be switched with #11, but concentration is consistent with that measured during cast TT012004 at this depth; probably okay
3	3	1	992.3	1000.2	Leaking from bottom o-ring; oxygen appears high and draw temperature high
3	4	8	60	60.3	Pretrip
4	7	nd	nd	nd	All depths: CTD salinity values starting to be affected by cracked conductivity sensor
4	8	nd	nd	nd	All depths: CTD salinity values starting to be affected by cracked conductivity sensor
4	9	nd	nd	nd	All depths: CTD salinity values staring to be affected by cracked conductivity sensor
4	9	1	4301.1	4369.3	Oxygen draw temperature high and concentration looks low; o-ring problem noted on salt log
5	10	nd	nd	nd	All depths: CTD salinity values starting to be affected by cracked conductivity sensor
5	10	11	14.8	14.9	Possible pretrip based on oxygen value and draw temperature
5	11	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	11	11	30.1	30.3	Possible pretrip based on oxygen value and draw temperature
5	12	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	12	11	14.6	14.6	Possible pretrip based on oxygen value and draw temperature
5	13	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	13	11	14.5	14.6	Possible pretrip based on oxygen value and draw temperature
5	13	10	30	30.2	Bottle leaking during sample draw
5	13	8	58.6	59	Possible pretrip based on oxygen value and draw temperature; salt value also low
5	13	7	74.1	74.5	Bottle leaking during sample draw
5	14	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	15	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	15	11	28.8	28.9	Possible pretrip based on oxygen value and draw temperature
5	15	10	98.5	99.1	Bottle leaking during sample draw
5	15	7	398.2	400.8	Bottle leaking during sample draw
5	15	1	993.5	1001.4	Bottom o-ring displaced; leaking; salinity high; oxygen concentration and draw temperature high
5	16	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	16	11	14.7	14.8	Possible pretrip based on oxygen value and draw temperature
5	16	10	30.1	30.3	Bottle leaking during sample draw
5	16	7	75.5	75.9	Bottle leaking during sample draw
5	16	4	121.6	122.3	Appears that bottle leaked; salinity high and oxygen low
5	17	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	18	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	19	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor; CTD pump hose came off
5	20	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	21	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	21	12	4.6	4.6	Probable pretrip; salinity high and oxygen concentration and draw temperature low
5	21	2	174.9	175.9	Air vent open; salt and oxygen appear okay
5	21	1	198.1	199.3	O-ring displaced; bottle leaking; oxygen concentration and draw temperature high
5	22	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	23	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	24	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	24	9	45.2	45.5	Bottle leaked; no salt or oxygen
5	24	1	398	400.6	Bottle leaked badly; salt and oxygen appear high
5	25	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	26	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	27	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	28	nd	nd	nd	All depths: CTD salinity values affected by cracked conductivity sensor
5	29	nd	nd	nd	All depths: no CTD data files available for this cast; depths are nominal based on standard 1000m cast
5	29	12	nd	0	Nominal depth
5	29	11	nd	30	Nominal depth
5	29	10	nd	100	Nominal depth
5	29	9	nd	200	Nominal depth; bottom o-ring leaking; salt and oxygen appear okay
5	29	8	nd	300	Nominal depth
5	29	7	nd	400	Nominal depth
5	29	6	nd	500	Nominal depth
5	29	5	nd	600	Nominal depth
5	29	4	nd	700	Nominal depth
5	29	3	nd	800	Nominal depth
5	29	2	nd	900	Nominal depth
5	29	1	nd	1000	Nominal depth
5	31	12	3.7	3.7	Oxygen concentration appears low; no analytical problems noted; salinity appears okay and draw temperature reasonable
5	31	1	199.1	200.3	O-ring displaced and bottle leaking; oxygen concentration and draw temperature appear high; salt also a little high
5	33	6	3450.6	3498.4	Air vent open; oxygen could have been contaminated; salinity looks okay
5	33	2	4306.3	4374.6	Problem with top o-ring; salinity and oxygen values both low for this depth; probable contamination
5	36	2	891.8	898.7	Bottle leaking during draw; salinity and oxygen appear okay
5	39	1	15.2	15.2	All twelve bottles tripped at this depth but only one scan of CTD data saved during bottle closings
5	41	12	3.3	3.3	Bottle did not close; lanyard hung up
5	43	11	15.3	15.4	Salinity appears low; no analytical problems noted
5	59	8	59.8	60.1	Pretrip; broken lanyard; salinity high and oxygen low for this depth
5	59	1	198.8	200	Oxygen value appears high; no analytical problems noted
5	66	12	3.8	3.8	Confusion about salinity sample numbers; best guess
5	66	11	14.6	14.7	Confusion about salinity sample numbers; best guess
5	66	10	30.5	30.7	Confusion about salinity sample numbers; best guess
5	67	11	29.5	29.7	Top o-ring displaced; salinity and oxygen appear okay
5	68	5	99.3	99.8	Salinity appears low; problems with Autosal during analyses from bottles 4 ,5, and 6 at this station
5	71	11	16	16	Salinity high; probable pretrip
5	71	2	173.2	174.3	Salinity a little low at this depth
5	79	11	30	30.2	Top o-ring displaced; salinity and oxygen appear okay
5	81	11	15.2	15.2	Pretrip; broken lanyard; salinity high and oxygen low
5	84	12	4.4	4.4	May have closed at 15 dbar; see note for bottle 9
5	84	11	15.3	15.4	May have closed at 31 dbar; see note for bottle 9
5	84	10	30.8	31	May have closed at 44 dbar; see note for bottle 9
5	84	9	44	44.2	Salinity value indicates double trip with bottle 8 at 60 dbar; if so, then bottles 10, 11, and 12 closed at wrong depths as indicated above
5	90	2	894.6	901.5	Deleted high oxygen value; no analytical problems noted; salt and draw temperature look okay