# James Murray
# EQPAC TT008
# Comments relating to quality (q_flag)
#
sta	ctd	bot	press_	depth_	comments
004	3	24	401.3	398.7	Bottle appears to have double-tripped with bottle #1 based on salinity and oxygen data, so no surface sample this station; other bottles (2-23) probably closed at intended depths
004	A04	23	nd	nd	Oxygen, salinity, and nutrients indicate bottle closed at about 100m
004	A04	21	nd	nd	Oxygen, salinity, and nutrients indicate bottle closed at about 250m
004	A04	19	nd	nd	Oxygen, salinity, and nutrients indicate bottle closed at about 500m
004	A04	17	nd	nd	Oxygen, salinity, and nutrients indicate bottle closed at about 750m
004	A04	15	nd	nd	Oxygen, salinity, and nutrients indicate bottle closed at about 1000m
004	A04	13	nd	nd	Oxygen, salinity, and nutrients indicate bottle closed at about 1500m
005	5	9	45.5	45.3	Bottle salinity seems low; no oxygen; check your data
005	5	5	105.3	104.7	Bottle salinity seems low; no oxygen; check your data
005	6	12	6.5	6.5	Bottle leaked while sampling
005	11	3	150.7	149.8	Bottle salinity seems low; no oxygen; check your data
005	13	12	4.6	4.5	Bottle leaked while sampling
005	15	6	90.7	90.2	Bottle salinity seems high; oxygen looks OK; possible double trip with bottle #5 at 100m
005	20	12	4.7	4.7	Oxygen seems high; no problem found
005	20	11	15.3	15.2	Oxygen seems high; no problem found
005	20	5	100.8	100.2	Oxygen seems a little high; no problem found
005	20	4	120.8	120.1	Oxygen seems a little high; no problem found
005	22	2	175.2	174.2	Oxygen seems high and salinity seems low; no analytical problems found; CTD salinity profile odd for top 90m of cast; check your data
005	24	12	5.4	5.4	CTD salinities bad for cast
005	24	11	30.2	30.1	CTD salinities bad for cast
005	24	10	100	99.4	Oxygen too low, nutrients too high for this depth; probable pretrip between 200-300m; CTD salinities bad for cast
005	24	9	199.7	198.5	CTD salinities bad for cast
005	24	8	300.4	298.6	Bottle leaked while sampling; o-ring askew; oxygen a little high; CTD salinities bad for cast
005	24	7	400.6	398	CTD salinities bad for cast
005	24	6	500.9	497.5	CTD salinities bad for cast
005	24	5	602	597.8	CTD salinities bad for cast
005	24	4	700.5	695.4	CTD salinities bad for cast
005	24	3	801	795.1	CTD salinities bad for cast
005	24	2	900.6	893.7	CTD salinities bad for cast
005	24	1	999.6	991.7	CTD salinities bad for cast
005	25	12	5.1	5	Bottle salinity seems high and oxygen too low for this depth; probable pretrip bewtween 150-175m
005	26	12	6.9	6.8	Bottle salinity seems low; oxygen looks OK; no problem found
005	29	8	59.6	59.2	Bottle leaked while sampling; o-ring askew; salinity looks OK; no oxygen
005	31	12	4.8	4.8	Bottle salinity seems low; oxygen looks OK; no problem found
005	37	8	60.8	60.5	O-ring askew
005	37	4	120.3	119.6	Bottle salinity seems high; oxygen looks OK; possible double trip with bottle #3 at 150m
005	37	2	175	174	Bottle leaked while sampling
005	39	4	120	119.3	Bottle salinity seems low; oxygen looks OK; no problem found
005	41	12	5	5	Oxygen seems high; salinity OK; no problem found
005	44	2	174.4	173.4	Lanyard broke; no water
005	46	8	300.5	298.7	Oxygen seems low; salinity OK; no problem found
005	48	12	5.3	5.3	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	48	11	15.7	15.7	Salinities appear drawn in reverse order for this cast; order changed to match profile; oxygen value seems high
005	48	10	30.9	30.7	Salinities appear drawn in reverse order for this cast; order changed to match profile; oxygen value seems high
005	48	9	45.2	44.9	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	48	8	62	61.7	Salinities appear drawn in reverse order for this cast; order changed to match profile; oxygen value too low for this depth, but no analytical problem found
005	48	7	75.9	75.5	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	48	6	89.7	89.2	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	48	5	100.5	99.9	Salinities appear drawn in reverse order for this cast; order changed to match profile; salinity and oxygen values seem low for this depth anyway; no analytical problem found
005	48	4	120.6	119.9	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	48	3	149.7	148.8	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	48	2	175.3	174.3	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	48	1	200.5	199.3	Salinities appear drawn in reverse order for this cast; order changed to match profile
005	49	8	300.6	298.8	Bottle leaked while sampling
005	52	8	300.2	298.3	Bottle leaked while sampling
005	54	7	75.2	74.8	Bottle leaked while sampling; CTD salinities noisy during this cast; pump hose off
005	57	8	60.3	59.9	Oxygen seems low; salinity OK; no problem found
005	57	4	120.7	120	Bottle leaked when vented
005	58	5	101.2	100.6	Bottle came up open; no water
005	59	7	75.4	75	Bottle leaked while sampling
005	60	10	30.8	30.6	Vent not tightly closed
005	60	9	45.8	45.6	O-ring askew; leaking
005	60	8	59.8	59.4	O-ring askew
005	60	7	75.8	75.4	Bottle leaked while sampling
005	61	7	75.4	75	Bottle salinity seems low; oxygen looks OK; no problem found
005	61	6	90.6	90.1	Oxygen seems high; no problem found
005	63	8	750.2	744.7	Bottle leaked while sampling; o-ring askew
005	63	7	1001	993.1	Bottle leaked when vented
005	63	3	3003.4	2965.8	Oxygen seems low; no problem found
007	66	7	77.6	77.2	Bottle leaked when vented
008	68	8	60	59.7	Bottle leaked while sampling; o-ring askew; no oxygen
008	69	7	1001	992.9	Bottle salinity seems high; no oxygen; sampling log indicated this bottle leaked